www.anatol.biz riders/reflex/technic.php Last modified: June 12 2009 11:48:14. requested by CCBot/2.0 (http://commoncrawl.org/faq/) @ 54.80.148.252:47008


Reflex - Technical Rider

ReFleX


technical rider

1. stage and set

The stage should be at least 6m wide and 6m deep (plus backstage and service area) and completely levelled.

The minimum height (fly bars if possible) should be at least 5m.

The stage floor should be non reflective black. There should be a black backdrop hung on the last flybar and we will use a typical italian scene with legs and teasers.
In addition we will set up a passepartout like frame 4m wide and about 3m high with two legs and one teaser.
We will need at least 6 2x1m risers at ca. 20cm height wich have to be covered with black dancefloor.

2. Material de iluminação

The houselights should be controlable by DMX512 and should not leak onto the stage.

Lighting material to be supplied by the venue:

5 of the PC's and 4 of the profiles will be placed on floor bases.

24 dimmer channels dmx512 with linear response (we will use very low intensities and very long fades)

dmx cable from the dimmers to the sound and lighting booth (male 3 pin used 1 - ground / 2 - positive / 3 - negative)

We will bring our own lighting desk with us.

For the needed cables please consult the sketch below.

3. Som

PA:

a 2 point source system (left/right und subs) each point granting full coverage of the audience (20Hz-20kHz @ 98dBa SPL) preserving 12dBu of headroom thruout the whole system.

Source:
1 professional CD player
there should be a graphic EQ (1/3 octave - 31 bands) for each PA and foldback send and a small mixer to control the levels.

The system should be ready to be set up upon our arrival.

3.Video

we will need a video beamer with about 2kL / contrast about 4000:0 to be set up at center downstage on the floor
it should be able to project a 4m by 3m undistorted image on our frame (see 1.) without leaks to the black drops
it will be driven by a PC from the booth, please provide ta proper connection for it (pref. VGA)

4. Sketches

in some systems this sketch might not be complete, for accurate information please refer to this file in AutoCad 3D 2004 DWG format, compressed DXF 3D or in encapsulated Postscript
depending on your connection and system this application might take up to 10 minutes to load

5. Working schedules




local technicians

dia

periódo

tasks

som

luz

rigg / mach

1

manhã

set up light / sound / stage set

1

2

1

afinação / patch

1

2

1

tarde

stage set up / light corrections / sound check

1

1

1

ensaio geral

1

1

1

night

performance / break down

1

1

1

6. dressing rooms

We will need a dressing room with shower facilities and a backup room for storage and production support.

7. laundry service

After or before the performance we will need to dry clean one white dress.

8. contacts

technical matters:
Anatol Waschke
anatol[at]anatol[dot]biz
+351 914 937 950
www.anatol.biz

production:
Via-Lab - Ana Martins
info[at]via-lab[dot]com
Tel. +351 965 201 811

document copyleft  by Anatol Waschke