vOId - Technical Rider

V O I D


© JPORTELA


technical rider

1. stage and set

The stage should be at least 10m wide and 10m deep (plus backstage and service area) and completely levelled.

The minimum height (fly bars if possible) should be at least 6m.

The stage floor should be covered with non reflective black dancefloor.
We'll use the stage with no drops or legs at all (open stage), therefore all the walls around the stage should as neutral coloured as possible (pref. black).
We will need teasers accordingly to the local conditions to hide the technical structures like cables and flybars.

2. Material de iluminação


Lighting material to be supplied by the venue:

  • 27 - PC's (PrismConvex) 1kW with barndoors and colourframe
  • 04 - PC's (PrismConvex) 2kw with barndoors and colourframe
  • 16 - PAR64 CP62
  • 01 - PAR64 CP61
  • 13 - recortes Robert Juliat 614SX
  • 01 - haze machine

48 dimmer channels dmx512 with linear response

dmx cable from the dimmers to the sound and lighting booth (male 3 pin used 1 - ground / 2 - positive / 3 - negative)

We will bring our own lighting desk with us.

For the needed cables please consult the sketch below.

3. Som

PA:
a 2 point source system (left/right und subs) each point granting full coverage of the audience (20Hz-20kHz @ 98dBa SPL) preserving 12dBu of headroom thruout the whole system.
for large venues we will need an additional central cluster
2 full range side fill monitors providing full stage coverage
2 floor monitors providing full stage coverage.

Source/Process:
there should be a graphic EQ (1/3 octave - 31 bands) for each PA and foldback send.

  • 1 - Lexicon MPX 1 ou semelhante

  • 1 - FOH mixing desk 16-4-2+1 (4 band param. EQ + reg. lowcut/ch)

  • 4 - Crown PCC 160

  • 2 - DPA 4060 (with floor adaptors)

The system should be ready to be set up upon our arrival.

4. Sketches

in some systems this sketch might not be completefor accurate information please refer to this file in AutoCad 3D 2004 DWG format, compressed DXF 3D or in encapsulated Postscript
depending on your connection and system this application might take up to 10 minutes to load

the drawing below is just an example, please send us a sketch of your venue we'll try to adapt the technical specifications.

5. Working schedule




local technicians

dia

periódo

tasks

som

luz

rigging

ajudantes

1

morning

setup set / light / sound

1

3

1

0

afternoon

focus

0

2

1

0

night

sound check / program

1

1

0

0

2

morning

break

0

0

0

0

afternoon

runthru / corrections

1

1

1

0

night

show

1

1

0

0

6. dressing rooms

We will need a dressing room for 2 dancers with shower facilities and a backup room for storage and production support.

7. laundry service

Laundry service for 5 black costumes. Washing and drying after the show.

8. contacts

technical matters:
Anatol Waschke
anatol[at]anatol[dot]biz
+351 914 937 950
www.anatol.biz

production:
Companhia Clara Andermatt
Rua dos Caetanos, #1, 3
1200-078 Lisboa | Portugal
Tel +351 213 470 333
Fax +351 213 470 334
GSM +351 968 707 686
acccandermatt[at]mail[dot]telepac[dot]pt
www.clara-andermatt.com

document copyleft  by Anatol Waschke